description: X-Powers AXP2101 power management IC include: ["i2c-device.yaml"] compatible: "x-powers,axp2101" properties: aldo1-millivolt: type: int default: 0 description: ALDO1 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. aldo1-enabled: type: boolean default: false description: Enable ALDO1 at driver start. aldo2-millivolt: type: int default: 0 description: ALDO2 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. aldo2-enabled: type: boolean default: false description: Enable ALDO2 at driver start. aldo3-millivolt: type: int default: 0 description: ALDO3 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. aldo3-enabled: type: boolean default: false description: Enable ALDO3 at driver start. aldo4-millivolt: type: int default: 0 description: ALDO4 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. aldo4-enabled: type: boolean default: false description: Enable ALDO4 at driver start. bldo1-millivolt: type: int default: 0 description: BLDO1 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. bldo1-enabled: type: boolean default: false description: Enable BLDO1 at driver start. bldo2-millivolt: type: int default: 0 description: BLDO2 output voltage in mV (500-3500, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. bldo2-enabled: type: boolean default: false description: Enable BLDO2 at driver start. cpusldo-millivolt: type: int default: 0 description: CPUSLDO output voltage in mV (500-1400, step 50), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. cpusldo-enabled: type: boolean default: false description: Enable CPUSLDO at driver start. dldo1-millivolt: type: int default: 0 description: DLDO1 output voltage in mV (500-3400, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. dldo1-enabled: type: boolean default: false description: Enable DLDO1 at driver start. dldo2-millivolt: type: int default: 0 description: DLDO2 output voltage in mV (500-3400, step 100), applied at driver start if non-zero. 0 leaves the channel's voltage untouched. dldo2-enabled: type: boolean default: false description: Enable DLDO2 at driver start.